Automatic Firefighting Water Monitor
Keywords: water monitor automatic water fire monitor
Automatic firefighting water monitor
Automatic firefighting monitor water cannons 30m
Automatic Firefighting Water Monitor Introductions:
Automatic Firefighting Water Monitor is the infrared sensor technology, signal processing communication technology, control technology, computer technology and mechanical technology organically unifies in together, can automatically monitor the fire within the scope of protection. Once the fire happens, fire extinguishing device immediately start, Intelligent scanning of fire source in horizontal and vertical direction, after determine fire two range, the central controller issued a directive, fire alarm signal is sent out, at the same time start the water pump, open the valve, fire extinguishing device for aiming put out the fire, after put out the fire, the central controller issued a directive stop jetting water. If there is a new fire, the fire distinguish device will repeat the process, until all the fire was put out to return to the monitoring state. 5L/s~10L/s full automatic fire monitor water jet form columnar water jet, for range, large scope of protection, extinguishing ability is very strong.
Automatic Firefighting Water Monitor Features:
Using dual band infrared and ultraviolet composite detection technology, find the fire early, high accuracy, wide range, without blind spots;
The position of the fire source can be fixed point and the positioning of the water spray fire extinguishing, and the efficiency of the early fire is high;
In fire scene, through 485 bus can manual control the water jetting direction of fire extinguish device nozzle
Using bus system image transmission technology , combined with the field of color image signal remote manual control;
Meet the requirements of the national standard manual, automatic and remote manual control of the three ways;
Bus communication, less material consumption, convenient construction, maintenance is simple and convenient;
Secondary search, no reset, greatly shortens extinguishing time
Can receive any other manufacturers’ fire automatic alarm system linkage signal;
Light weight, compact in shape, generous and beautiful.
Automatic Firefighting Water Monitor Parameters:
Radius of Protection
|
30m
|
35m
|
60m
|
Water Jetting Flow
|
5L/s
|
10L/s
|
30L/s
|
Overall dimensions (LXWXH)
|
400mmx380mmx450mm
|
400mmx380mmx450mm
|
582mmx320mmx310mm
|
Weight
|
8KG
|
9KG
|
17KG
|
Interface diameter
|
DN32
|
DN32
|
DN80
|
Installation height
|
4-30m
|
4-30m
|
6-30m
|
Rated working pressure
|
0.6Mpa
|
0.6Mpa
|
0.6Mpa
|
Max. Working pressure
|
1.0Mpa
|
1.0Mpa
|
1.0Mpa
|
Voltage/Power
|
AC220V/Monitoring:1W, scan:50W
|
AC220V/Monitoring:1W, scan:50W
|
AC220V/Monitoring:1W, scan:50W
|
Communication mode
|
RS485(communication with field area controller)
|
RS485(communication with field area controller)
|
RS485(communication with field area controller)
|
The fire location time
|
≤30s
|
≤30s
|
≤35s
|
Working environment temperature
|
-20℃~80℃
|
-20℃~80℃
|
-20℃~80℃
|
Horizontal rotation range
|
0~360°(adjustable)
|
0~360°(adjustable)
|
0~360°(adjustable)
|
Vertical rotation range
|
-10°~+90°
|
-10°~+90°
|
-70°~+90°
|
Jet water mode
|
Reciprocating swing after straight injection
|
Reciprocating swing after straight injection
|
Reciprocating swing after straight injection
|